10 Fun Facts for DNA Electrophoresis

::

Migration of DNA is retarded and band distortion can occur when too much buffer covers the gel. The slower migration results from a reduced voltage gradient across the gel.

::

Loading DNA in the smallest volume possible will result in sharper bands.

::

You can preserve DNA in agarose gels for long-term storage using 70% ethanol. [See Jacobs, D. and Neilan, B.A. (1995) BioTechniques 19, 892.]

::

Electrophoresing a gel too "hot" can cause the DNA to denature in the gel. It can also cause the agarose gel to deform. Cool the gel with a small fan during the electrophoresis.

::

You can preserve DNA in agarose gels for long-term storage using 70% ethanol. [See Jacobs, D. and Neilan, B.A. (1995) BioTechniques 19, 892.]

::

Electrophoresing a gel too "hot" can cause the DNA to denature in the gel. It can also cause the agarose gel to deform. Cool the gel with a small fan during the electrophoresis.

::

For the Supercoiled DNA Ladder electrophoresed on <1% agarose gels, add 2 1lg/ml ethidium bromide to the gel. Otherwise, smeared bands and extra bands will be seen because of different degrees of supercoiling. [See Longo, M.C. and Hartley, J.L. (1986) Focus 8:3, 3. (reprinted on page 63, this issue).]

::

When glycerol-containing loading buffers are used in DNA samples electrophoresed through acrylamide gels, smiling bands may be accentuated especially in TBE.

::

On a polyacrylamide gel, DNA fragments having AT-rich regions migrate slower than other DNA fragments of the same size. This anomalous migration is enhanced at lower temperatures and disappears at high temperatures. This anomalous migration is not observed on agarose gels. [See Stellwagen, N.C. (1983) Biochemistry22, 6186.]

::

The minimum amount of DNA detectable by ethidium bromide on a 3-mm-thick gel and a 5-mm-wide lane is 1 ng. Do not exceed 50 ng of DNA per band on a 3-mm-thick gel and 5-mm-wide lane.

TROUBLESHOOTING DNA AGAROSE GEL ELECTROPHORESIS

If you see faint or no bands on the gel:

   
::

There was insufficient quantity or concentration of DNA loaded on the gel. Increase the amount of DNA, but don't exceed 50 ng/band.

::

The DNA was degraded. Avoid nuclease contamination.

::

The DNA was electrophoresed off the gel. Electrophorese the gel for less time, use a lower voltage, or use a higher percent gel.

::

Improper W light source was used for visualization of ethidium bromide-stained DNA. Use a shortwavelength (254 nm) W light for greater sensitivity. Note: For preparative gels, using a longer wavelength (312 nm) W light will minimize DNA degradation.

   

If you see smeared DNA bands:

   
::

The DNA was degraded. Avoid nuclease contamination.

::

Too much DNA was loaded on the gel. Decrease the amount of DNA.

::

Improper electrophoresis conditions were used. Do not allow voltage to exceed ~20 V/cm. Maintain a temperature <30° C during electrophoresis. Check that the electrophoresis buffer used had sufficient buffer capacity. This is done by checking the pH in the anode and cathode chambers.

::

There was too much salt in the DNA. Use ethanol precipitation to remove excess salts, prior to electrophoresis.

::

The DNA was contaminated with protein. Use phenol extractions to remove protein prior to electrophoresis.

::

Small DNA bands diffused during staining. Add the
ethidium bromide during electrophoresis.

 

If you see anomalies DNA band migration:

   
::

Improper electrophoresis conditions were used. Do not allow voltage to exceed ~20 V/cm. Maintain a temperature <30° C during electrophoresis. Check that the electrophoresis buffer used had sufficient buffer capacity.

::

The DNA was denatured. Do not heat standards [except for l DNA/Hind III fragments prior to electrophoresis. Dilute DNA standards in buffer with 20 mM NaCl.

关闭窗口打印该页
本信息真实性未经证实,仅供您参考。未经许可,不得转载。
关于我们 | 广告合作 | 联系我们 | 友情连接 | 诚聘英才 | 网站地图 | 网上有名 | 加入收藏 | 意见反馈
版权所有:生技网-生物门户-生物技术-生物界权威门户网站 http://www.biogo.net/
服务热线:010-63831637 010-63834699 传真: 010-63831637
E-Mail: biogo#biogo.net(#换成@)
Copyright2006 - 2007, sionbiocorp.All Rights Reserved. 京ICP备05052705号